Skip to content
Nidexa Jeneratör
Call
Baudouin 165 kVA Diesel Generator

Image is for illustration purposes only.

Baudouin Generators

Baudouin 165 kVA Diesel Generator

The Baudouin 165 kVA diesel generator delivers 165 kVA / 132 kW in standby duty and 150 kVA / 120 kW in prime duty. Power comes from a 6-cylinder, 6.75-litre BAUDOUIN 6M11G165/5 turbocharged aftercooled engine with a 400/230 V, 50 Hz three-phase output.

Standby Power (ESP)
165kVA· 132 kW
Prime Power (PRP)
150kVA· 120 kW
6M11G165/5France50 Hz400/230 V
Call Now

Technical Specifications

Power & Electrical

Standby Power (ESP)
165 kVA / 132 kW / 238 A
Prime Power (PRP)
150 kVA / 120 kW / 217 A
Voltage
400/230 V
Frequency
50 Hz
Phase
3
Power Factor
0.8

Engine

Engine Brand
Baudouin
Engine Model
6M11G165/5
Cylinders
6 / Inline
Displacement
6.75 L
Bore x Stroke
105 x 130 mm
Compression Ratio
18:1
Aspiration
Turbocharged Aftercooled
Cooling System Capacity
25
Fuel Consumption (100% load)
32.6 L/h
Fuel Consumption (75% load)
24.3 L/h

Alternator

Voltage / Frequency
400/230 V - 50 Hz
Phase
3
Power Factor
0.8
Insulation Class
H
Protection Class
IP23

Dimensions

Canopied Type (L x W x H)
3400 x 1150 x 1750 mm
Open Type (L x W)
2500 x 1150 mm

Product Information

Category
Baudouin Generators
Stock Code
NDX-BAU-165
Warranty
24 months
Country of Origin
Türkiye

Overview

Baudouin 165 kVA Diesel Generator

Sizing a generator is less about the headline rating than about how the load actually behaves over time. This set is rated 165 kVA / 132 kW for standby duty, where it carries the site during a mains failure, and 150 kVA / 120 kW for prime duty under continuous running. The margin between the two ratings leaves headroom for the inrush of motor-driven equipment. Calculated at a 0.8 power factor, the unit fits installations drawing around 120 kW of active load.

Engine

A BAUDOUIN 6M11G165/5 diesel engine drives the set. The block is a 6-cylinder inline design of 6.75 litres, with a 105 x 130 mm bore and stroke and an 18:1 compression ratio. A turbocharged aftercooled intake cools the charge air before combustion. Fuel consumption is 32.6 L/h at full load and 24.3 L/h at 75% load, and the stated cooling capacity figure is 25.

Alternator and Electrical Data

The alternator runs at 400/230 V and 50 Hz in a three-phase configuration with a 0.8 power factor. Output current is 238 A in standby duty and 217 A in prime duty, the figures that govern switchgear and cable sizing. Winding insulation is class H and the protection rating is IP23.

  • Standby power: 165 kVA / 132 kW / 238 A
  • Prime power: 150 kVA / 120 kW / 217 A
  • Voltage and frequency: 400/230 V, 50 Hz, 3 phase
  • Engine: BAUDOUIN 6M11G165/5, 6-cylinder inline, 6.75 L
  • Intake: turbocharged aftercooled, 18:1 compression ratio
  • Insulation class H, protection class IP23
  • Fuel consumption: 32.6 L/h at 100% load, 24.3 L/h at 75% load

Installation and Use

The canopied version measures 3400 x 1150 x 1750 mm, while the open-frame version occupies a 2500 x 1150 mm footprint. Allow headroom above the canopied unit; the open set is intended for a dedicated plant room. Supplied under the Nidexa name, the generator originates from Türkiye and carries a 24-month warranty. Stock code: NDX-BAU-165.

SEND ENQUIRY

Fill out the form and we will get back to you as soon as we can.

Enquiry Type

By submitting this form, you have read and agree to our Privacy Policy and Data Protection Notice.

WE ARE HERE TO HELP

Talk to an expert about the right generator for you.