Image is for illustration purposes only.
Shanghai Dongfeng Generator
Shanghai Dongfeng 450 kVA Diesel Generator
The Shanghai Dongfeng 450 kVA diesel generator is powered by an SDEC SC13H460D2 engine and delivers 450 kVA / 360 kW standby and 410 kVA / 328 kW prime. The 12.8 litre six cylinder unit provides a three phase 400/230 V, 50 Hz output in canopy or open frame form.
- Standby Power (ESP)
- 450kVA· 360 kW
- Prime Power (PRP)
- 410kVA· 328 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 450 kVA / 360 kW / 650 A
- Prime Power (PRP)
- 410 kVA / 328 kW / 592 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Shanghai Dongfeng
- Engine Model
- SC13H460D2
- Cylinders
- 6 / Inline
- Displacement
- 12.8 L
- Bore x Stroke
- 128 x 153 mm
- Compression Ratio
- 16:1
- Aspiration
- Turbocharged Aftercooled
- Cooling System Capacity
- 65
- Fuel Consumption (100% load)
- 94 L/h
- Fuel Consumption (75% load)
- 70.5 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 4200 x 1500 x 2150 mm
- Open Type (L x W)
- 3100 x 1500 mm
Product Information
- Category
- Shanghai Dongfeng Generator
- Stock Code
- NDX-SDF-450
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Shanghai Dongfeng 450 kVA Diesel Generator
This 450 kVA diesel generating set is built on a body whose footprint can be planned long before delivery. The canopy version measures 4200 x 1500 x 2150 mm, while the open frame version occupies 3100 x 1500 mm, so door width, ceiling height and manoeuvring clearance in the generator room can be checked while the layout is still on paper. Standby output is 450 kVA / 360 kW and prime output is 410 kVA / 328 kW.
Engine
Power comes from an SDEC SC13H460D2. The inline six cylinder block displaces 12.8 litres, with a bore and stroke of 128 x 153 mm and a compression ratio of 16:1. A turbocharged, aftercooled intake cools the charge air before it reaches the cylinders. Fuel consumption is stated as 94 L/h at 100% load and 70.5 L/h at 75% load, two figures that feed directly into tank sizing and refuelling intervals.
Alternator and Electrical Data
The alternator output is 400/230 V at 50 Hz, three phase, rated at a power factor of 0.8. Windings use class H insulation and the enclosure carries IP23 protection. On the current side the set reaches 650 A at standby rating and 592 A at prime rating, and these values govern switchboard selection, cable cross section and breaker sizing.
- Standby power (ESP): 450 kVA / 360 kW / 650 A
- Prime power (PRP): 410 kVA / 328 kW / 592 A
- Engine: SDEC SC13H460D2, inline 6 cylinder, 12.8 L
- Bore x stroke 128 x 153 mm, compression ratio 16:1
- Intake: turbocharged, aftercooled
- Voltage and frequency: 400/230 V, 50 Hz, 3 phase, power factor 0.8
- Insulation class H, protection class IP23
- Fuel consumption: 94 L/h (100% load), 70.5 L/h (75% load)
Installation and Use
The canopy version suits installations placed directly in an open yard or plant area; at 2150 mm tall, crane and forklift access should be measured in advance. The open frame version needs only 3100 x 1500 mm and fits an existing generator room or a container build. Stock code NDX-SDF-450, origin Türkiye, covered by a 24 month warranty.