Image is for illustration purposes only.
Baudouin Generators
Baudouin 25 kVA Diesel Generator
A 25 kVA diesel generating set built around the Baudouin 4M06G25/5 engine, rated 25 kVA / 20 kW standby and 22.7 kVA / 18 kW prime. The 2.3 litre naturally aspirated four-cylinder drives a 400/230 V, 50 Hz three-phase alternator.
- Standby Power (ESP)
- 25kVA· 20 kW
- Prime Power (PRP)
- 22.7kVA· 18 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 25 kVA / 20 kW / 36 A
- Prime Power (PRP)
- 22.7 kVA / 18 kW / 33 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Baudouin
- Engine Model
- 4M06G25/5
- Cylinders
- 4 / Inline
- Displacement
- 2.3 L
- Bore x Stroke
- 89 x 92 mm
- Compression Ratio
- 17.5:1
- Aspiration
- Natural Aspiration
- Cooling System Capacity
- 16
- Fuel Consumption (100% load)
- 6.1 L/h
- Fuel Consumption (75% load)
- 4.5 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 2000 x 950 x 1260 mm
- Open Type (L x W)
- 1700 x 950 mm
Product Information
- Category
- Baudouin Generators
- Stock Code
- NDX-BAU-25
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Baudouin 25 kVA Diesel Generator: Engine Architecture and Mechanical Layout
What defines this set is the mechanical layout of the Baudouin 4M06G25/5 engine. Its 2.3 litre displacement is divided across four cylinders arranged inline, with an 89 mm bore working against a 92 mm stroke. A compression ratio of 17.5:1 and a naturally aspirated intake keep the air path free of a turbocharger unit. In this configuration the set is rated at 25 kVA standby and 22.7 kVA prime power.
Engine
The engine is a BAUDOUIN 4M06G25/5: four cylinders in a single row, 2.3 L displacement, 89 x 92 mm bore and stroke, and a 17.5:1 compression ratio. Aspiration is natural and the stated cooling capacity is 16. Diesel consumption is 6.1 L/h at 100% load and 4.5 L/h at 75% load, so part-load running can be planned against two reference figures.
Alternator and Electrical Data
The alternator delivers 400/230 V at 50 Hz in a three-phase configuration with a 0.8 power factor. In standby (ESP) duty the ratings are 25 kVA / 20 kW at 36 A; in prime (PRP) duty they are 22.7 kVA / 18 kW at 33 A. Winding insulation is class H and the protection rating is IP23.
- Standby power (ESP): 25 kVA / 20 kW / 36 A
- Prime power (PRP): 22.7 kVA / 18 kW / 33 A
- Engine: BAUDOUIN 4M06G25/5, 4 cylinders inline, 2.3 L
- Bore x stroke 89 x 92 mm, compression ratio 17.5:1, natural aspiration
- Voltage and frequency: 400/230 V, 50 Hz, 3 phase, power factor 0.8
- Insulation class H, protection class IP23
- Fuel consumption: 6.1 L/h at 100% load, 4.5 L/h at 75% load
- Stock code NDX-BAU-25, origin Turkey
Installation and Use
Two body forms define the footprint. In canopy form the set measures 2000 x 950 x 1260 mm (L x W x H), while the open version is 1700 x 950 mm in length and width; these dimensions feed directly into layout and transport-route planning. The set originates from Turkey, carries a 24-month warranty and is tracked under stock code NDX-BAU-25.