Image is for illustration purposes only.
Yangdong Generator
Yangdong 70 kVA Diesel Generator
Powered by the Yangdong Y4108ZLD engine, this 70 kVA diesel generator delivers 55.2 kW in standby duty and 62.5 kVA / 50 kW in prime duty. A 4.4 litre four cylinder turbocharged intercooled engine and a 400/230 V 50 Hz three phase output make it suitable for both canopied and open frame installation.
- Standby Power (ESP)
- 70kVA· 55.2 kW
- Prime Power (PRP)
- 62.5kVA· 50 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 70 kVA / 55.2 kW / 101 A
- Prime Power (PRP)
- 62.5 kVA / 50 kW / 90 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Yangdong
- Engine Model
- Y4108ZLD
- Cylinders
- 4 / Inline
- Displacement
- 4.4 L
- Bore x Stroke
- 108 x 120 mm
- Compression Ratio
- 18:1
- Aspiration
- Turbocharged Intercooled
- Cooling System Capacity
- 16
- Fuel Consumption (100% load)
- 15 L/h
- Fuel Consumption (75% load)
- 11.2 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 2400 x 1000 x 1500 mm
- Open Type (L x W)
- 2100 x 1000 mm
Product Information
- Category
- Yangdong Generator
- Stock Code
- NDX-YAN-70
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Yangdong 70 kVA Diesel Generator
The figures that decide where this 70 kVA set can actually go start with its footprint. The canopied body measures 2400 x 1000 x 1500 mm, while the open frame version occupies 2100 x 1000 mm, so the space needed in a plant room, at a basement entrance or on an outdoor slab can be fixed at the drawing stage. The constant 1000 mm width keeps the unit manageable through narrow passages.
Engine
Power comes from the Yangdong Y4108ZLD diesel engine, a four cylinder inline unit of 4.4 litres with a bore and stroke of 108 x 120 mm and an 18:1 compression ratio. Air is supplied through a turbocharged, intercooled intake that cools the charge air before it reaches the cylinders. Fuel consumption is 15 L/h at 100% load and 11.2 L/h at 75% load.
Alternator and Electrical Data
The alternator supplies 400/230 V at 50 Hz across three phases, with a power factor of 0.8. In standby duty (ESP) the set reaches 70 kVA / 55.2 kW at 101 A, while prime duty (PRP) is rated at 62.5 kVA / 50 kW at 90 A. The windings use class H insulation and the housing carries an IP23 protection rating.
- Standby power (ESP): 70 kVA / 55.2 kW / 101 A
- Prime power (PRP): 62.5 kVA / 50 kW / 90 A
- Engine: Yangdong Y4108ZLD, 4 cylinders, inline, 4.4 L
- Intake: turbocharged intercooled, 18:1 compression ratio
- Voltage and frequency: 400/230 V, 50 Hz, 3 phase, 0.8 power factor
- Class H insulation, IP23 protection rating
- Fuel consumption: 15 L/h at 100% load, 11.2 L/h at 75% load
- Canopied dimensions: 2400 x 1000 x 1500 mm, open type: 2100 x 1000 mm
Installation and Use
The canopied build suits outdoor placements, while the open frame is the practical choice when the set goes inside a plant room. The 1500 mm canopy height should be checked against transport routes and door openings during planning. The generator is manufactured in Türkiye and comes with a 24 month warranty.