Image is for illustration purposes only.
Baudouin Generators
Baudouin 350 kVA Diesel Generator
The Baudouin 350 kVA diesel generator is rated at 350 kVA standby and 318 kVA prime power. It is driven by a 9.73 litre turbocharged, aftercooled BAUDOUIN 6M16G350/5 engine and delivers a 400/230 V, 50 Hz three-phase output.
- Standby Power (ESP)
- 350kVA· 280 kW
- Prime Power (PRP)
- 318kVA· 254 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 350 kVA / 280 kW / 505 A
- Prime Power (PRP)
- 318 kVA / 254 kW / 459 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Baudouin
- Engine Model
- 6M16G350/5
- Cylinders
- 6 / Inline
- Displacement
- 9.73 L
- Bore x Stroke
- 126 x 130 mm
- Compression Ratio
- 17:1
- Aspiration
- Turbocharged Aftercooled
- Cooling System Capacity
- 44
- Fuel Consumption (100% load)
- 66.4 L/h
- Fuel Consumption (75% load)
- 49.8 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 4000 x 1400 x 2100 mm
- Open Type (L x W)
- 3000 x 1400 mm
Product Information
- Category
- Baudouin Generators
- Stock Code
- NDX-BAU-350
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Baudouin 350 kVA Diesel Generator
The Baudouin 350 kVA diesel generator is dimensioned for sites where the layout is settled long before the set arrives. In the canopy version it measures 4000 x 1400 x 2100 mm, while the open frame version occupies a 3000 x 1400 mm footprint, so the unit can sit in a plant room, in a technical yard or on a prepared concrete pad. Both body options share the same 1400 mm width, which lets access routes and service clearances be planned around a single figure.
Engine
Power comes from a BAUDOUIN 6M16G350/5 unit. The 9.73 litre inline six cylinder block runs a bore and stroke of 126 x 130 mm with a 17:1 compression ratio, and breathes through a turbocharged, aftercooled intake. Fuel consumption is quoted as 66.4 L/h at full load and 49.8 L/h at 75 percent load, two figures that feed straight into tank sizing and daily refuelling schedules.
Alternator and Electrical Data
The alternator supplies 400/230 V at 50 Hz in a three-phase arrangement, with a power factor of 0.8. Output current reaches 505 A in standby and 459 A in continuous operation, and switchgear selection and cable cross sections are calculated from these values. Winding insulation is class H and enclosure protection is IP23.
- Standby power (ESP): 350 kVA / 280 kW / 505 A
- Prime power (PRP): 318 kVA / 254 kW / 459 A
- Engine: BAUDOUIN 6M16G350/5, inline 6 cylinder, 9.73 L
- Turbocharged and aftercooled intake, 17:1 compression ratio
- Output: 400/230 V, 50 Hz, 3 phase, power factor 0.8
- Insulation class H, protection class IP23
- Fuel consumption: 66.4 L/h (100%), 49.8 L/h (75%)
- Model: Baudouin 350 kVA, stock code NDX-BAU-350
Installation and Use
With an overall canopy height of 2100 mm, ceiling clearance and the exhaust run are resolved around that dimension. The open frame version, at 3000 x 1400 mm, gives a more compact layout on projects where the plant room already exists. The generator is of Turkish origin and is covered by a 24 month warranty.