Skip to content
Nidexa Jeneratör
Call
Baudouin 55 kVA Diesel Generator

Image is for illustration purposes only.

Baudouin Generators

Baudouin 55 kVA Diesel Generator

The Nidexa Baudouin 55 kVA diesel generator pairs a turbocharged BAUDOUIN 4M06G55/5 engine with 55 kVA standby (44 kW) and 50 kVA prime output, delivering 400/230 V, 50 Hz three-phase power at 11.9 L/h fuel consumption under full load.

Standby Power (ESP)
55kVA· 44 kW
Prime Power (PRP)
50kVA· 40 kW
4M06G55/5France50 Hz400/230 V
Call Now

Technical Specifications

Power & Electrical

Standby Power (ESP)
55 kVA / 44 kW / 79 A
Prime Power (PRP)
50 kVA / 40 kW / 72 A
Voltage
400/230 V
Frequency
50 Hz
Phase
3
Power Factor
0.8

Engine

Engine Brand
Baudouin
Engine Model
4M06G55/5
Cylinders
4 / Inline
Displacement
2.3 L
Bore x Stroke
89 x 92 mm
Compression Ratio
17.5:1
Aspiration
Turbocharged
Cooling System Capacity
13
Fuel Consumption (100% load)
11.9 L/h
Fuel Consumption (75% load)
8.9 L/h

Alternator

Voltage / Frequency
400/230 V - 50 Hz
Phase
3
Power Factor
0.8
Insulation Class
H
Protection Class
IP23

Dimensions

Canopied Type (L x W x H)
2300 x 950 x 1560 mm
Open Type (L x W)
2000 x 950 mm

Product Information

Category
Baudouin Generators
Stock Code
NDX-BAU-55
Warranty
24 months
Country of Origin
Türkiye

Overview

Baudouin 55 kVA Diesel Generator

The real cost of a generator is not settled at purchase; it accumulates in every running hour. The Nidexa Baudouin 55 kVA diesel generator burns 11.9 litres per hour at 100% load and 8.9 litres per hour at 75% load, which keeps the operating budget calculable from the outset. The higher the annual running hours, the more that gap shows up on the fuel bill. With 44 kW of standby power and 40 kW of prime power, the set is sized for facilities that spend long stretches on partial load.

Engine

The unit is built around the BAUDOUIN 4M06G55/5 engine: four cylinders in an inline layout, 2.3 litres of displacement, an 89 x 92 mm bore and stroke, and a 17.5:1 compression ratio. Turbocharged aspiration draws up to 44 kW from that compact displacement while keeping fuel use proportional to load.

Alternator and Electrical Data

The alternator is rated at 400/230 V and 50 Hz across three phases, so the set connects directly to three-phase distribution. At a 0.8 power factor the output current is 79 A in standby duty and 72 A in prime duty, and those figures are the starting point for switchgear and cable sizing. Windings use class H insulation and the enclosure carries an IP23 protection rating.

  • Standby power (ESP): 55 kVA / 44 kW / 79 A
  • Prime power (PRP): 50 kVA / 40 kW / 72 A
  • Engine: BAUDOUIN 4M06G55/5, 4-cylinder inline, 2.3 L, turbocharged
  • Voltage and frequency: 400/230 V, 50 Hz, 3-phase, 0.8 power factor
  • Fuel consumption: 11.9 L/h at 100% load, 8.9 L/h at 75% load
  • Bore x stroke 89 x 92 mm, compression ratio 17.5:1
  • Class H insulation, IP23 protection rating
  • Stock code: NDX-BAU-55

Installation and Operation

The canopied set measures 2300 x 950 x 1560 mm, while the open-type skid footprint is 2000 x 950 mm, figures that feed straight into layout and service-access planning. The generator originates from Türkiye and is covered by a 24-month warranty.

SEND ENQUIRY

Fill out the form and we will get back to you as soon as we can.

Enquiry Type

By submitting this form, you have read and agree to our Privacy Policy and Data Protection Notice.

WE ARE HERE TO HELP

Talk to an expert about the right generator for you.