Image is for illustration purposes only.
Baudouin Generators
Baudouin 55 kVA Diesel Generator
The Nidexa Baudouin 55 kVA diesel generator pairs a turbocharged BAUDOUIN 4M06G55/5 engine with 55 kVA standby (44 kW) and 50 kVA prime output, delivering 400/230 V, 50 Hz three-phase power at 11.9 L/h fuel consumption under full load.
- Standby Power (ESP)
- 55kVA· 44 kW
- Prime Power (PRP)
- 50kVA· 40 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 55 kVA / 44 kW / 79 A
- Prime Power (PRP)
- 50 kVA / 40 kW / 72 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Baudouin
- Engine Model
- 4M06G55/5
- Cylinders
- 4 / Inline
- Displacement
- 2.3 L
- Bore x Stroke
- 89 x 92 mm
- Compression Ratio
- 17.5:1
- Aspiration
- Turbocharged
- Cooling System Capacity
- 13
- Fuel Consumption (100% load)
- 11.9 L/h
- Fuel Consumption (75% load)
- 8.9 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 2300 x 950 x 1560 mm
- Open Type (L x W)
- 2000 x 950 mm
Product Information
- Category
- Baudouin Generators
- Stock Code
- NDX-BAU-55
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Baudouin 55 kVA Diesel Generator
The real cost of a generator is not settled at purchase; it accumulates in every running hour. The Nidexa Baudouin 55 kVA diesel generator burns 11.9 litres per hour at 100% load and 8.9 litres per hour at 75% load, which keeps the operating budget calculable from the outset. The higher the annual running hours, the more that gap shows up on the fuel bill. With 44 kW of standby power and 40 kW of prime power, the set is sized for facilities that spend long stretches on partial load.
Engine
The unit is built around the BAUDOUIN 4M06G55/5 engine: four cylinders in an inline layout, 2.3 litres of displacement, an 89 x 92 mm bore and stroke, and a 17.5:1 compression ratio. Turbocharged aspiration draws up to 44 kW from that compact displacement while keeping fuel use proportional to load.
Alternator and Electrical Data
The alternator is rated at 400/230 V and 50 Hz across three phases, so the set connects directly to three-phase distribution. At a 0.8 power factor the output current is 79 A in standby duty and 72 A in prime duty, and those figures are the starting point for switchgear and cable sizing. Windings use class H insulation and the enclosure carries an IP23 protection rating.
- Standby power (ESP): 55 kVA / 44 kW / 79 A
- Prime power (PRP): 50 kVA / 40 kW / 72 A
- Engine: BAUDOUIN 4M06G55/5, 4-cylinder inline, 2.3 L, turbocharged
- Voltage and frequency: 400/230 V, 50 Hz, 3-phase, 0.8 power factor
- Fuel consumption: 11.9 L/h at 100% load, 8.9 L/h at 75% load
- Bore x stroke 89 x 92 mm, compression ratio 17.5:1
- Class H insulation, IP23 protection rating
- Stock code: NDX-BAU-55
Installation and Operation
The canopied set measures 2300 x 950 x 1560 mm, while the open-type skid footprint is 2000 x 950 mm, figures that feed straight into layout and service-access planning. The generator originates from Türkiye and is covered by a 24-month warranty.