Image is for illustration purposes only.
Perkins Generator
Perkins 150 kVA Diesel Generator
Powered by a Perkins 1106A-70TG1 engine, this 150 kVA diesel generator delivers 150 kVA / 120 kW standby and 135 kVA / 108 kW prime power. Its turbocharged 7-litre block and three-phase 400/230 V, 50 Hz output suit sites that cannot tolerate a gap in supply.
- Standby Power (ESP)
- 150kVA· 120 kW
- Prime Power (PRP)
- 135kVA· 108 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 150 kVA / 120 kW / 217 A
- Prime Power (PRP)
- 135 kVA / 108 kW / 195 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 1106A-70TG1
- Cylinders
- 6 / Inline
- Displacement
- 7 L
- Bore x Stroke
- 105 x 135 mm
- Compression Ratio
- 18.2:1
- Aspiration
- Turbocharged
- Cooling System Capacity
- 21
- Fuel Consumption (100% load)
- 30.2 L/h
- Fuel Consumption (75% load)
- 22.7 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 3400 x 1150 x 1750 mm
- Open Type (L x W)
- 2500 x 1150 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-150
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 150 kVA Diesel Generator (NDX-PER-150)
A mains failure costs exactly as long as the pause it forces on a production line, a chilled store or a server room. This Nidexa generating set is rated at 150 kVA / 120 kW in standby duty and 135 kVA / 108 kW in prime duty, so the decision between covering short interruptions and carrying a load for extended hours rests on published figures rather than assumptions.
Engine
The set is built around a Perkins 1106A-70TG1: six cylinders in an inline arrangement, 7 litres of displacement, a 105 x 135 mm bore and stroke and an 18.2:1 compression ratio. Aspiration is turbocharged, which keeps charge density up as load is applied. Fuel consumption is quoted at 30.2 L/h at full load and 22.7 L/h at 75 percent load, giving two reference points for sizing the tank and planning refuelling intervals.
Alternator and Electrical Data
The alternator supplies 400/230 V at 50 Hz across three phases at a 0.8 power factor. Output current reaches 217 A in standby duty and 195 A in prime duty. Windings use class H insulation and the housing carries an IP23 protection rating.
- Standby power (ESP): 150 kVA / 120 kW / 217 A
- Prime power (PRP): 135 kVA / 108 kW / 195 A
- Engine: Perkins 1106A-70TG1, 6-cylinder inline, 7 L, turbocharged
- Bore x stroke 105 x 135 mm, compression ratio 18.2:1
- Voltage and frequency: 400/230 V, 50 Hz, 3 phase, 0.8 power factor
- Class H insulation, IP23 protection rating
- Fuel consumption: 30.2 L/h at 100 percent load, 22.7 L/h at 75 percent load
- Stock code: NDX-PER-150
Installation and Use
In canopied form the set measures 3400 x 1150 x 1750 mm and suits an outdoor position. The open version takes up a 2500 x 1150 mm footprint, which is easier to place inside a plant room. Work these dimensions into the layout together with the exhaust route and the ventilation openings before the base is prepared. The unit is manufactured in Türkiye and comes with a 24-month warranty.