Image is for illustration purposes only.
Perkins Generator
Perkins 220 kVA Diesel Generator
A 220 kVA diesel generating set built around the PERKINS 1106A-70TAG4 engine, rated 220 kVA / 176 kW in standby duty and 200 kVA / 160 kW in prime duty. Its three-phase 400/230 V, 50 Hz alternator uses class H insulation and an IP23 protection rating.
- Standby Power (ESP)
- 220kVA· 176 kW
- Prime Power (PRP)
- 200kVA· 160 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 220 kVA / 176 kW / 318 A
- Prime Power (PRP)
- 200 kVA / 160 kW / 289 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 1106A-70TAG4
- Cylinders
- 6 / Inline
- Displacement
- 7 L
- Bore x Stroke
- 105 x 135 mm
- Compression Ratio
- 16:1
- Aspiration
- Turbocharged Air-Air
- Cooling System Capacity
- 21
- Fuel Consumption (100% load)
- 45.1 L/h
- Fuel Consumption (75% load)
- 34.6 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 3700 x 1200 x 1900 mm
- Open Type (L x W)
- 2800 x 1200 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-220
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 220 kVA Diesel Generator: Electrical Performance and Alternator Design
The Nidexa Perkins 220 kVA generating set produces three-phase power at 400/230 V and 50 Hz. At a power factor of 0.8 it is rated 220 kVA / 176 kW with 318 A in standby (ESP) duty, and 200 kVA / 160 kW with 289 A in prime (PRP) duty. These two ratings draw a clear line between emergency backup service and continuous operation under load.
Engine
Power comes from the PERKINS 1106A-70TAG4 diesel engine, a 6-cylinder inline unit with a displacement of 7 L. It runs a bore and stroke of 105 x 135 mm and a compression ratio of 16:1. Aspiration is Turbocharged Air-Air, meaning turbocharging with air-to-air charge cooling. Fuel consumption is stated as 45.1 L/hour at 100% load and 34.6 L/hour at 75% load.
Alternator and Electrical Ratings
The alternator is rated 400/230 V - 50 Hz, three-phase, at a power factor of 0.8. Winding insulation is class H and the enclosure protection rating is IP23. Class H covers withstand capability at high winding temperatures, while IP23 defines protection against solid objects and against water falling at an angle. Output current reaches 318 A in standby and 289 A in continuous duty.
- Standby power (ESP): 220 kVA / 176 kW / 318 A
- Prime power (PRP): 200 kVA / 160 kW / 289 A
- Voltage and frequency: 400/230 V, 50 Hz, 3 phase
- Power factor: 0.8
- Engine: PERKINS 1106A-70TAG4, 6-cylinder inline, 7 L
- Insulation class H, protection class IP23
- Fuel consumption: 45.1 L/hour at 100% load, 34.6 L/hour at 75% load
- Stock code: NDX-PER-220
Installation and Use
Both canopied and open-type body dimensions are defined for this set. The canopied version measures 3700 x 1200 x 1900 mm (L x W x H) and the open type measures 2800 x 1200 mm (L x W), figures that govern the layout of a generator room or an outdoor pad. The product originates from Türkiye and is covered by a 24-month warranty. Model: Perkins 220 kVA, stock code NDX-PER-220.