Skip to content
Nidexa Jeneratör
Call
Perkins 220 kVA Diesel Generator

Image is for illustration purposes only.

Perkins Generator

Perkins 220 kVA Diesel Generator

A 220 kVA diesel generating set built around the PERKINS 1106A-70TAG4 engine, rated 220 kVA / 176 kW in standby duty and 200 kVA / 160 kW in prime duty. Its three-phase 400/230 V, 50 Hz alternator uses class H insulation and an IP23 protection rating.

Standby Power (ESP)
220kVA· 176 kW
Prime Power (PRP)
200kVA· 160 kW
1106A-70TAG4UK50 Hz400/230 V
Call Now

Technical Specifications

Power & Electrical

Standby Power (ESP)
220 kVA / 176 kW / 318 A
Prime Power (PRP)
200 kVA / 160 kW / 289 A
Voltage
400/230 V
Frequency
50 Hz
Phase
3
Power Factor
0.8

Engine

Engine Brand
Perkins
Engine Model
1106A-70TAG4
Cylinders
6 / Inline
Displacement
7 L
Bore x Stroke
105 x 135 mm
Compression Ratio
16:1
Aspiration
Turbocharged Air-Air
Cooling System Capacity
21
Fuel Consumption (100% load)
45.1 L/h
Fuel Consumption (75% load)
34.6 L/h

Alternator

Voltage / Frequency
400/230 V - 50 Hz
Phase
3
Power Factor
0.8
Insulation Class
H
Protection Class
IP23

Dimensions

Canopied Type (L x W x H)
3700 x 1200 x 1900 mm
Open Type (L x W)
2800 x 1200 mm

Product Information

Category
Perkins Generator
Stock Code
NDX-PER-220
Warranty
24 months
Country of Origin
Türkiye

Overview

Perkins 220 kVA Diesel Generator: Electrical Performance and Alternator Design

The Nidexa Perkins 220 kVA generating set produces three-phase power at 400/230 V and 50 Hz. At a power factor of 0.8 it is rated 220 kVA / 176 kW with 318 A in standby (ESP) duty, and 200 kVA / 160 kW with 289 A in prime (PRP) duty. These two ratings draw a clear line between emergency backup service and continuous operation under load.

Engine

Power comes from the PERKINS 1106A-70TAG4 diesel engine, a 6-cylinder inline unit with a displacement of 7 L. It runs a bore and stroke of 105 x 135 mm and a compression ratio of 16:1. Aspiration is Turbocharged Air-Air, meaning turbocharging with air-to-air charge cooling. Fuel consumption is stated as 45.1 L/hour at 100% load and 34.6 L/hour at 75% load.

Alternator and Electrical Ratings

The alternator is rated 400/230 V - 50 Hz, three-phase, at a power factor of 0.8. Winding insulation is class H and the enclosure protection rating is IP23. Class H covers withstand capability at high winding temperatures, while IP23 defines protection against solid objects and against water falling at an angle. Output current reaches 318 A in standby and 289 A in continuous duty.

  • Standby power (ESP): 220 kVA / 176 kW / 318 A
  • Prime power (PRP): 200 kVA / 160 kW / 289 A
  • Voltage and frequency: 400/230 V, 50 Hz, 3 phase
  • Power factor: 0.8
  • Engine: PERKINS 1106A-70TAG4, 6-cylinder inline, 7 L
  • Insulation class H, protection class IP23
  • Fuel consumption: 45.1 L/hour at 100% load, 34.6 L/hour at 75% load
  • Stock code: NDX-PER-220

Installation and Use

Both canopied and open-type body dimensions are defined for this set. The canopied version measures 3700 x 1200 x 1900 mm (L x W x H) and the open type measures 2800 x 1200 mm (L x W), figures that govern the layout of a generator room or an outdoor pad. The product originates from Türkiye and is covered by a 24-month warranty. Model: Perkins 220 kVA, stock code NDX-PER-220.

SEND ENQUIRY

Fill out the form and we will get back to you as soon as we can.

Enquiry Type

By submitting this form, you have read and agree to our Privacy Policy and Data Protection Notice.

WE ARE HERE TO HELP

Talk to an expert about the right generator for you.

Perkins 220 kVA Diesel Generator | Nidexa Jeneratör