Perkins Generator
Perkins 200 kVA Diesel Generator
The Nidexa 200 kVA diesel generator is driven by a Perkins 1106A-70TAG3 engine and delivers 200 kVA / 160 kW standby and 180 kVA / 144 kW prime power. Its three-phase alternator operates at 400/230 V, 50 Hz with class H insulation and IP23 protection.
- Standby Power (ESP)
- 200kVA· 160 kW
- Prime Power (PRP)
- 180kVA· 144 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 200 kVA / 160 kW / 289 A
- Prime Power (PRP)
- 180 kVA / 144 kW / 260 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 1106A-70TAG3
- Cylinders
- 6 / Inline
- Displacement
- 7 L
- Bore x Stroke
- 105 x 135 mm
- Compression Ratio
- 16:1
- Aspiration
- Turbocharged Air-Air
- Cooling System Capacity
- 21
- Fuel Consumption (100% load)
- 41.6 L/h
- Fuel Consumption (75% load)
- 31 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 3600 x 1200 x 1850 mm
- Open Type (L x W)
- 2700 x 1200 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-200
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 200 kVA Diesel Generator (NDX-PER-200)
This Nidexa generating set is defined first of all by its electrical output and alternator behaviour. In standby duty (ESP) it produces 200 kVA / 160 kW at 289 A, while in prime duty (PRP) it delivers 180 kVA / 144 kW at 260 A. Because every figure refers to a 0.8 power factor and a 400/230 V supply, the three-phase load distribution of the installation can be planned directly from these current ratings.
Engine
The set is powered by a Perkins 1106A-70TAG3 diesel engine. It has 6 cylinders in an inline layout, a displacement of 7 litres, a bore and stroke of 105 x 135 mm and a compression ratio of 16:1. The aspiration type is specified as Turbocharged Air-Air. Fuel consumption is 41.6 L/hour at 100% load and 31 L/hour at 75% load.
Alternator and Electrical Ratings
The alternator runs at 400/230 V, 50 Hz in a 3-phase configuration with a power factor of 0.8. Insulation is class H and the protection rating is IP23. Switchgear, cable cross-sections and protective devices should be selected on the basis of the 289 A standby and 260 A prime current ratings.
- Standby power (ESP): 200 kVA / 160 kW / 289 A
- Prime power (PRP): 180 kVA / 144 kW / 260 A
- Engine: Perkins 1106A-70TAG3, 6 cylinders, inline, 7 L
- Bore x stroke: 105 x 135 mm, compression ratio 16:1
- Aspiration: Turbocharged Air-Air
- Alternator: 400/230 V, 50 Hz, 3-phase, power factor 0.8
- Insulation class H, protection class IP23
- Fuel consumption: 41.6 L/hour at 100% load, 31 L/hour at 75% load
Installation and Use
The canopied version measures 3600 x 1200 x 1850 mm, while the open type measures 2700 x 1200 mm, so the generator room or outdoor pad should be laid out to suit these dimensions. The set carries the stock code NDX-PER-200, originates from Türkiye and is covered by a 24-month warranty.