Perkins 200 kVA Diesel Generator

Image is for illustration purposes only.

Perkins Generator

Perkins 200 kVA Diesel Generator

The Nidexa 200 kVA diesel generator is driven by a Perkins 1106A-70TAG3 engine and delivers 200 kVA / 160 kW standby and 180 kVA / 144 kW prime power. Its three-phase alternator operates at 400/230 V, 50 Hz with class H insulation and IP23 protection.

Standby Power (ESP)
200kVA· 160 kW
Prime Power (PRP)
180kVA· 144 kW
1106A-70TAG3UK50 Hz400/230 V
Call Now

Technical Specifications

Power & Electrical

Standby Power (ESP)
200 kVA / 160 kW / 289 A
Prime Power (PRP)
180 kVA / 144 kW / 260 A
Voltage
400/230 V
Frequency
50 Hz
Phase
3
Power Factor
0.8

Engine

Engine Brand
Perkins
Engine Model
1106A-70TAG3
Cylinders
6 / Inline
Displacement
7 L
Bore x Stroke
105 x 135 mm
Compression Ratio
16:1
Aspiration
Turbocharged Air-Air
Cooling System Capacity
21
Fuel Consumption (100% load)
41.6 L/h
Fuel Consumption (75% load)
31 L/h

Alternator

Voltage / Frequency
400/230 V - 50 Hz
Phase
3
Power Factor
0.8
Insulation Class
H
Protection Class
IP23

Dimensions

Canopied Type (L x W x H)
3600 x 1200 x 1850 mm
Open Type (L x W)
2700 x 1200 mm

Product Information

Category
Perkins Generator
Stock Code
NDX-PER-200
Warranty
24 months
Country of Origin
Türkiye

Overview

Perkins 200 kVA Diesel Generator (NDX-PER-200)

This Nidexa generating set is defined first of all by its electrical output and alternator behaviour. In standby duty (ESP) it produces 200 kVA / 160 kW at 289 A, while in prime duty (PRP) it delivers 180 kVA / 144 kW at 260 A. Because every figure refers to a 0.8 power factor and a 400/230 V supply, the three-phase load distribution of the installation can be planned directly from these current ratings.

Engine

The set is powered by a Perkins 1106A-70TAG3 diesel engine. It has 6 cylinders in an inline layout, a displacement of 7 litres, a bore and stroke of 105 x 135 mm and a compression ratio of 16:1. The aspiration type is specified as Turbocharged Air-Air. Fuel consumption is 41.6 L/hour at 100% load and 31 L/hour at 75% load.

Alternator and Electrical Ratings

The alternator runs at 400/230 V, 50 Hz in a 3-phase configuration with a power factor of 0.8. Insulation is class H and the protection rating is IP23. Switchgear, cable cross-sections and protective devices should be selected on the basis of the 289 A standby and 260 A prime current ratings.

  • Standby power (ESP): 200 kVA / 160 kW / 289 A
  • Prime power (PRP): 180 kVA / 144 kW / 260 A
  • Engine: Perkins 1106A-70TAG3, 6 cylinders, inline, 7 L
  • Bore x stroke: 105 x 135 mm, compression ratio 16:1
  • Aspiration: Turbocharged Air-Air
  • Alternator: 400/230 V, 50 Hz, 3-phase, power factor 0.8
  • Insulation class H, protection class IP23
  • Fuel consumption: 41.6 L/hour at 100% load, 31 L/hour at 75% load

Installation and Use

The canopied version measures 3600 x 1200 x 1850 mm, while the open type measures 2700 x 1200 mm, so the generator room or outdoor pad should be laid out to suit these dimensions. The set carries the stock code NDX-PER-200, originates from Türkiye and is covered by a 24-month warranty.