Perkins Generator
Perkins 275 kVA Diesel Generator
The Perkins 275 kVA diesel generator pairs a 6-cylinder Perkins 1206A-E70TTAG3 engine with 275 kVA standby and 250 kVA prime output at 400/230 V, 50 Hz. Fuel consumption is 56 litres per hour at full load and 42 litres per hour at 75 percent load.
- Standby Power (ESP)
- 275kVA· 220 kW
- Prime Power (PRP)
- 250kVA· 200 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 275 kVA / 220 kW / 397 A
- Prime Power (PRP)
- 250 kVA / 200 kW / 361 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 1206A-E70TTAG3
- Cylinders
- 6 / Inline
- Displacement
- 7 L
- Bore x Stroke
- 105 x 135 mm
- Compression Ratio
- 16:1
- Aspiration
- Turbocharged Air-Air
- Cooling System Capacity
- 25
- Fuel Consumption (100% load)
- 56 L/h
- Fuel Consumption (75% load)
- 42 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 3900 x 1300 x 2000 mm
- Open Type (L x W)
- 2900 x 1300 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-275
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 275 kVA Diesel Generator
The running cost of a generating set is settled at the fuel tank, and the figures for this unit are plain: 56 litres per hour at full load and 42 litres per hour at 75 percent load. That 14 litre gap for every hour of operation is what turns load planning into a budget decision on sites that run long shifts. Keeping the set inside its 250 kVA prime band instead of pushing it toward the 275 kVA standby ceiling is therefore the single clearest lever on operating economy.
Engine
At the core of the set sits the Perkins 1206A-E70TTAG3, a 6-cylinder inline diesel with 7 litres of displacement. Bore and stroke measure 105 x 135 mm, so the stroke is longer than the bore, and the compression ratio is 16:1. Aspiration is turbocharged air-to-air, meaning charge air passes through an air-to-air cooler after the turbocharger before it reaches the cylinders.
Alternator and Electrical Data
The alternator delivers 3-phase power at 400/230 V and 50 Hz, rated at a 0.8 power factor. In standby duty that corresponds to 220 kW and 397 A; in prime duty it corresponds to 200 kW and 361 A. The windings use class H insulation and the enclosure carries an IP23 protection rating.
- Standby power (ESP): 275 kVA / 220 kW / 397 A
- Prime power (PRP): 250 kVA / 200 kW / 361 A
- Engine: Perkins 1206A-E70TTAG3, 6-cylinder, inline, 7 L
- Bore x stroke 105 x 135 mm, compression ratio 16:1, turbocharged air-to-air
- Voltage and frequency: 400/230 V, 50 Hz, 3-phase, power factor 0.8
- Fuel consumption: 56 L/h at 100% load, 42 L/h at 75% load
- Class H insulation, IP23 protection
- Stock code: NDX-PER-275
Installation and Use
The set can be specified as a canopied unit measuring 3900 x 1300 x 2000 mm or as an open version with a 2900 x 1300 mm skid footprint, so the layout follows whether the machine sits in a plant room or on an outdoor pad. Allow clearance around these dimensions for service access and ventilation air. The generator is manufactured in Türkiye and carries a 24-month warranty.