Image is for illustration purposes only.
Perkins Generator
Perkins 300 kVA Diesel Generator
Powered by a Perkins 1506A-E88TAG4 engine, this Nidexa 300 kVA diesel generator delivers 300 kVA / 240 kW in standby and 275 kVA / 220 kW in prime operation. Its 400/230 V, 50 Hz three-phase output is available in canopy or open-frame form.
- Standby Power (ESP)
- 300kVA· 240 kW
- Prime Power (PRP)
- 275kVA· 220 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 300 kVA / 240 kW / 433 A
- Prime Power (PRP)
- 275 kVA / 220 kW / 397 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 1506A-E88TAG4
- Cylinders
- 6 / Inline
- Displacement
- 8.8 L
- Bore x Stroke
- 112 x 149 mm
- Compression Ratio
- 16.1:1
- Aspiration
- Turbocharged Air-Air
- Cooling System Capacity
- 29.6
- Fuel Consumption (100% load)
- 60 L/h
- Fuel Consumption (75% load)
- 45 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 4000 x 1400 x 2100 mm
- Open Type (L x W)
- 3000 x 1400 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-300
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 300 kVA Diesel Generator (NDX-PER-300)
This 300 kVA class generator suits projects where the layout has to be fixed early. In canopy form the unit measures 4000 x 1400 x 2100 mm, so the space needed in a plant room or on an outdoor pad can be calculated before the order is placed. The open-frame version occupies a 3000 x 1400 mm footprint, which makes it easier to drop onto a prepared concrete base or into an existing generator room. Cable routes, exhaust outlets and ventilation openings can all be planned against these exact figures.
Engine
The power source is the 8.8 litre Perkins 1506A-E88TAG4 diesel engine. Its inline block carries 6 cylinders with a bore and stroke of 112 x 149 mm and a compression ratio of 16.1:1. Aspiration is turbocharged with air-to-air charge cooling (Turbocharged Air-Air). Fuel consumption is 60 L/h at 100% load and 45 L/h at 75% load, figures that feed directly into daily consumption and refuelling interval calculations.
Alternator and Electrical Values
Alternator output is 400/230 V at 50 Hz across 3 phases, rated at a 0.8 power factor. Standby (ESP) operation gives 300 kVA / 240 kW / 433 A, while prime (PRP) operation gives 275 kVA / 220 kW / 397 A. The windings use class H insulation and the enclosure carries an IP23 protection rating. Switchgear and cable sizing should be based on the 433 A standby current.
- Standby power (ESP): 300 kVA / 240 kW / 433 A
- Prime power (PRP): 275 kVA / 220 kW / 397 A
- Engine: Perkins 1506A-E88TAG4, 6 cylinders inline, 8.8 L
- Voltage and frequency: 400/230 V, 50 Hz, 3 phase
- Class H insulation, IP23 protection rating
- Fuel consumption: 60 L/h at 100% load, 45 L/h at 75% load
Installation and Use
The canopy version measures 4000 x 1400 x 2100 mm and the open-frame body has a 3000 x 1400 mm footprint, so handling and base preparation follow those dimensions. The unit carries a 24 month warranty, originates from Türkiye and is listed under stock code NDX-PER-300.