Skip to content
Nidexa Jeneratör
Call
Perkins 400 kVA Diesel Generator

Image is for illustration purposes only.

Perkins Generator

Perkins 400 kVA Diesel Generator

Built around the Perkins 2206A-E13TAG2 engine, the Nidexa NDX-PER-400 is rated at 400 kVA standby and 350 kVA prime power. It delivers 400/230 V, 50 Hz three phase output and measures 4500 x 1600 x 2200 mm in the canopy version.

Standby Power (ESP)
400kVA· 320 kW
Prime Power (PRP)
350kVA· 280 kW
2206A-E13TAG2UK50 Hz400/230 V
Call Now

Technical Specifications

Power & Electrical

Standby Power (ESP)
400 kVA / 320 kW / 577 A
Prime Power (PRP)
350 kVA / 280 kW / 505 A
Voltage
400/230 V
Frequency
50 Hz
Phase
3
Power Factor
0.8

Engine

Engine Brand
Perkins
Engine Model
2206A-E13TAG2
Cylinders
6 / Inline
Displacement
12.5 L
Bore x Stroke
130 x 157 mm
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-Air
Cooling System Capacity
51.4
Fuel Consumption (100% load)
81 L/h
Fuel Consumption (75% load)
62 L/h

Alternator

Voltage / Frequency
400/230 V - 50 Hz
Phase
3
Power Factor
0.8
Insulation Class
H
Protection Class
IP23

Dimensions

Canopied Type (L x W x H)
4500 x 1600 x 2200 mm
Open Type (L x W)
3300 x 1600 mm

Product Information

Category
Perkins Generator
Stock Code
NDX-PER-400
Warranty
24 months
Country of Origin
Türkiye

Overview

Perkins 400 kVA Diesel Generator (NDX-PER-400)

When the site layout is drawn up, dimensions decide where this set can actually go. In the canopy version it occupies 4500 x 1600 x 2200 mm, while the open frame version drops to a 3300 x 1600 mm footprint. That gap drives the choice between an indoor generator room and an outdoor pad, and the 2200 mm height means door openings and overhead clearances should be measured beforehand.

Engine

Power comes from the Perkins 2206A-E13TAG2 engine. The 12.5 litre inline six cylinder block has a bore and stroke of 130 x 157 mm and a compression ratio of 16.3:1. Aspiration is turbocharged air to air. Fuel consumption is 81 L/hour at 100% load and 62 L/hour at 75% load, with a stated cooling capacity of 51.4.

Alternator and Electrical Values

Output is 400/230 V at 50 Hz across three phases, rated at a 0.8 power factor. In standby duty the set delivers 400 kVA / 320 kW and 577 A; in prime duty it delivers 350 kVA / 280 kW and 505 A. Winding insulation is class H and the protection rating is IP23.

  • Standby power (ESP): 400 kVA / 320 kW / 577 A
  • Prime power (PRP): 350 kVA / 280 kW / 505 A
  • Engine: Perkins 2206A-E13TAG2, 6 cylinder inline, 12.5 L
  • Voltage and frequency: 400/230 V, 50 Hz, 3 phase
  • Insulation class H, protection class IP23
  • Fuel consumption: 81 L/hour at 100% load, 62 L/hour at 75% load
  • Canopy dimensions: 4500 x 1600 x 2200 mm
  • Stock code: NDX-PER-400

Installation and Use

The canopy version suits outdoor placement, while the open frame version fits facilities that already have a generator room. Width stays at 1600 mm in both cases, so access corridor planning is identical. The unit carries a 24 month warranty and its country of origin is Türkiye.

SEND ENQUIRY

Fill out the form and we will get back to you as soon as we can.

Enquiry Type

By submitting this form, you have read and agree to our Privacy Policy and Data Protection Notice.

WE ARE HERE TO HELP

Talk to an expert about the right generator for you.