Perkins 500 kVA Diesel Generator

Image is for illustration purposes only.

Perkins Generator

Perkins 500 kVA Diesel Generator

Diesel generator powered by the Perkins 2506A-E15TAG2: six cylinders in line, 15.2 L displacement and turbocharged air-to-air aspiration, rated at 500 kVA standby and 450 kVA prime power. Output is 400/230 V, 50 Hz, three-phase.

Standby Power (ESP)
500kVA· 400 kW
Prime Power (PRP)
450kVA· 360 kW
2506A-E15TAG2UK50 Hz400/230 V
Call Now

Technical Specifications

Power & Electrical

Standby Power (ESP)
500 kVA / 400 kW / 722 A
Prime Power (PRP)
450 kVA / 360 kW / 650 A
Voltage
400/230 V
Frequency
50 Hz
Phase
3
Power Factor
0.8

Engine

Engine Brand
Perkins
Engine Model
2506A-E15TAG2
Cylinders
6 / Inline
Displacement
15.2 L
Bore x Stroke
137 x 171 mm
Compression Ratio
16:1
Aspiration
Turbocharged Air-Air
Cooling System Capacity
58
Fuel Consumption (100% load)
100 L/h
Fuel Consumption (75% load)
76 L/h

Alternator

Voltage / Frequency
400/230 V - 50 Hz
Phase
3
Power Factor
0.8
Insulation Class
H
Protection Class
IP23

Dimensions

Canopied Type (L x W x H)
4500 x 1600 x 2200 mm
Open Type (L x W)
3300 x 1600 mm

Product Information

Category
Perkins Generator
Stock Code
NDX-PER-500
Warranty
24 months
Country of Origin
Türkiye

Overview

Perkins 500 kVA Diesel Generator

The Perkins 500 kVA diesel generator is built around the mechanical architecture of the 2506A-E15TAG2 engine. Its 15.2-litre displacement is derived from a 137 mm bore and a 171 mm stroke, a long-stroke layout that puts the emphasis on torque production in the lower speed range. The 16:1 compression ratio and the turbocharged, air-to-air charge-cooled intake are the two elements that shape engine behaviour under load at the 500 kVA standby rating.

Engine

The Perkins 2506A-E15TAG2 has six cylinders in an inline arrangement. The 15.2 L displacement comes from bore and stroke figures of 137 x 171 mm, with a compression ratio of 16:1 and turbocharged air-to-air aspiration. Fuel consumption is stated as 100 L/h at 100% load and 76 L/h at 75% load. These figures serve as reference points when sizing the fuel tank to a site's daily running profile.

Alternator and Electrical Ratings

The alternator output is 400/230 V at 50 Hz, three-phase, calculated at a power factor of 0.8. In standby service (ESP) the set is rated at 500 kVA / 400 kW and 722 A; in prime service (PRP) the figures are 450 kVA / 360 kW and 650 A. Winding insulation is class H and the protection rating is IP23.

  • Standby power (ESP): 500 kVA / 400 kW / 722 A
  • Prime power (PRP): 450 kVA / 360 kW / 650 A
  • Engine: Perkins 2506A-E15TAG2, 6 cylinders inline, 15.2 L
  • Bore x stroke 137 x 171 mm, compression ratio 16:1
  • Aspiration: turbocharged, air-to-air charge cooled
  • Voltage and frequency: 400/230 V, 50 Hz, 3 phase, power factor 0.8
  • Insulation class H, protection class IP23
  • Fuel consumption: 100 L/h at 100% load, 76 L/h at 75% load

Installation and Operation

Canopied dimensions are 4500 x 1600 x 2200 mm (L x W x H), while the open-type version measures 3300 x 1600 mm (L x W), so the installation layout follows whichever configuration is chosen. The unit originates from Türkiye and the warranty period is 24 months. The model designation is Perkins 500 kVA and the stock code is NDX-PER-500.