The Perkins 450 kVA diesel generator is built around a 6-cylinder, 12.5-litre PERKINS 2206A-E13TAG3 engine and delivers 450 kVA standby and 400 kVA prime power, with a 400/230 V, 50 Hz three-phase output and class H winding insulation.
- Standby Power (ESP)
- 450kVA· 360 kW
- Prime Power (PRP)
- 400kVA· 320 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 450 kVA / 360 kW / 650 A
- Prime Power (PRP)
- 400 kVA / 320 kW / 577 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 2206A-E13TAG3
- Cylinders
- 6 / Inline
- Displacement
- 12.5 L
- Bore x Stroke
- 130 x 157 mm
- Compression Ratio
- 16.3:1
- Aspiration
- Turbocharged Air-Air
- Cooling System Capacity
- 51.4
- Fuel Consumption (100% load)
- 92 L/h
- Fuel Consumption (75% load)
- 68 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 4500 x 1600 x 2200 mm
- Open Type (L x W)
- 3300 x 1600 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-450
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 450 kVA Diesel Generator
The Perkins 450 kVA generating set is built on the PERKINS 2206A-E13TAG3, a six-cylinder inline diesel engine of 12.5 litres. A 130 x 157 mm bore and stroke, a 16.3:1 compression ratio and turbocharged air-to-air aspiration are the three elements that shape the mechanical character of the set. Together they support steady operation under load in the 450 kVA standby and 400 kVA prime power class.
Engine
The 2206A-E13TAG3 spreads its 12.5 L displacement across six cylinders in an inline arrangement. A 130 mm bore combined with a 157 mm stroke gives the engine a long-stroke character, while the 16.3:1 compression ratio governs how the diesel charge burns. Turbocharged air-to-air aspiration cools the charge air before it reaches the cylinders. Fuel consumption is 92 L/h at 100% load and 68 L/h at 75% load.
Alternator and Electrical Ratings
The set runs at 400/230 V, 50 Hz, three phase, with a power factor of 0.8 taken as the reference. In standby duty it supplies 450 kVA / 360 kW at 650 A; in prime duty it supplies 400 kVA / 320 kW at 577 A. Winding insulation is specified as class H and the protection rating as IP23.
- Standby power (ESP): 450 kVA / 360 kW / 650 A
- Prime power (PRP): 400 kVA / 320 kW / 577 A
- Engine: PERKINS 2206A-E13TAG3, 6 cylinders, inline, 12.5 L
- Bore x stroke: 130 x 157 mm, compression ratio 16.3:1
- Aspiration: turbocharged, air-to-air
- Electrical: 400/230 V, 50 Hz, 3 phase, power factor 0.8
- Insulation class H, protection class IP23
- Fuel consumption: 92 L/h at 100% load, 68 L/h at 75% load
Installation and Use
The canopied version measures 4500 x 1600 x 2200 mm (L x W x H), while the open set is listed with a 3300 x 1600 mm footprint. These figures should drive the layout of the generator room or the concrete base. The unit originates from Türkiye, is listed under stock code NDX-PER-450 and is covered by a 24-month warranty.