Perkins Generator
Perkins 72 kVA Diesel Generator
The Perkins 72 kVA diesel generator is built around a Perkins 1104A-44TG1 engine and delivers 72 kVA / 57.6 kW standby and 65 kVA / 52 kW prime power. Its 400/230 V, 50 Hz three-phase output and turbocharged 4.4-litre engine suit both canopied and open-frame installations.
- Standby Power (ESP)
- 72kVA· 57.6 kW
- Prime Power (PRP)
- 65kVA· 52 kW
Technical Specifications
Power & Electrical
- Standby Power (ESP)
- 72 kVA / 57.6 kW / 104 A
- Prime Power (PRP)
- 65 kVA / 52 kW / 94 A
- Voltage
- 400/230 V
- Frequency
- 50 Hz
- Phase
- 3
- Power Factor
- 0.8
Engine
- Engine Brand
- Perkins
- Engine Model
- 1104A-44TG1
- Cylinders
- 4 / Inline
- Displacement
- 4.4 L
- Bore x Stroke
- 105 x 127 mm
- Compression Ratio
- 17.25:1
- Aspiration
- Turbocharged
- Cooling System Capacity
- 13
- Fuel Consumption (100% load)
- 14.8 L/h
- Fuel Consumption (75% load)
- 11.2 L/h
Alternator
- Voltage / Frequency
- 400/230 V - 50 Hz
- Phase
- 3
- Power Factor
- 0.8
- Insulation Class
- H
- Protection Class
- IP23
Dimensions
- Canopied Type (L x W x H)
- 2400 x 1000 x 1500 mm
- Open Type (L x W)
- 2100 x 1000 mm
Product Information
- Category
- Perkins Generator
- Stock Code
- NDX-PER-72
- Warranty
- 24 months
- Country of Origin
- Türkiye
Overview
Perkins 72 kVA Diesel Generator (NDX-PER-72)
Deciding where a generator goes usually starts with its footprint. The Perkins 72 kVA diesel generator measures 2400 x 1000 x 1500 mm in canopied form, while the open-frame version has a 2100 x 1000 mm base. With both figures on the drawing, the choice between a plant room, a rooftop platform and an outdoor slab can be settled at the design stage, access clearance included. The set is rated at 72 kVA / 57.6 kW standby and 65 kVA / 52 kW prime.
Engine
Power comes from the Perkins 1104A-44TG1. It is an inline four-cylinder unit of 4.4 litres, with a bore and stroke of 105 x 127 mm and a compression ratio of 17.25:1. Aspiration is turbocharged. Fuel consumption is stated as 14.8 L/h at 100% load and 11.2 L/h at 75% load, which feeds straight into tank sizing and refuelling intervals for the expected daily run time.
Alternator and Electrical Data
The alternator output is 400/230 V at 50 Hz in a three-phase configuration. Ratings assume a power factor of 0.8, giving 104 A in standby operation and 94 A in continuous operation. Winding insulation is class H and the enclosure protection rating is IP23. These figures are the starting point for switchgear selection and cable sizing.
- Standby power (ESP): 72 kVA / 57.6 kW / 104 A
- Prime power (PRP): 65 kVA / 52 kW / 94 A
- Engine: Perkins 1104A-44TG1, 4 cylinders, 4.4 L, turbocharged
- Voltage and frequency: 400/230 V, 50 Hz, 3-phase
- Power factor: 0.8
- Insulation class H, protection class IP23
- Fuel consumption: 14.8 L/h at 100%, 11.2 L/h at 75%
- Stock code: NDX-PER-72
Installation and Use
The canopied version, at 2400 x 1000 x 1500 mm, is suited to outdoor placement, while the open-frame version with its 2100 x 1000 mm base fits sites that already have a dedicated plant room. The unit originates from Türkiye and carries a 24-month warranty.